企业新闻

江阴市云峰钢绳制品有限公司欢迎需要钢丝绳和镀锌钢丝绳的客户前来咨询.

« 对冷硬低铬钼球铁轧辊组织和硬度影响的退火温度

Reducer installation and use of the eight main points to note

Reducer is a common Power transmission organizations, in both mechanical drive system in a variety of applications. mat machine directly related to the installation and use of the running gear effect, to meet the technical specifications and standards. Reducer installation and use reasonable, pay attention to the following matters.

1, the reducer in the installation, paying particular attention to the axis of the transmission center of the error can not exceed the reducer coupling used in the use of compensation. Reducer in accordance with the requirements of, you can get better performance and longer transmission life.

2, the output shaft gear transmission parts in the installation, you must pay attention to the soft operation, prohibit the use of tools such as hammers brutal installation, it is best to use the assembly fixture and end thread shaft installed to the strength of the bolt screwed into the pressed into gear transmission parts, which can protect the internal parts of gear will not be damaged.

3, the mattress machine coupling used in a variety of optional type, but best not to use steel of a fixed coupling, such coupling is more difficult to install, once installed properly it will increase the load capacity, easily lead to bearing damage and even cause the output shaft fracture.

4, the fixed gear is very important to ensure a smooth and solid, in general, we should gear mounted on a foundation or base level, but should be able to discharge the oil tank removed, and the circulation of cooling air flow. The fixed gear is not good, basic unreliable, there will be caused, vibration and so on, will make the bearings and gears are unnecessary damage.

5, transmission couplings Drilling rig should be installed where necessary, protective devices, such as fasteners or protrusions on gear, sprocket and so on, if the output of the radial bearing loads by greater use should be enhanced.

6, the reducer is installed to ensure the operation of the staff, including the ability to conveniently close to the cursor, ventilation and other plug and oil drain plug location. water well drilling rig installation is complete, the inspector shall order a comprehensive check the accuracy of the installation location to determine the reliability of the various fasteners.

7, before running gear, but also ready to run, will remove the oil tank vent plug into vent plug, open the oil level plug screw check the oil line height, add the oil than the oil level plug screw to the hole overflow, then twist and determine the correct oil level plug, you can start trial operation.

8, reducer test run time can not be less than two hours in normal operation of the standard, smooth running, no vibration, no noise, no leakage, no impact, if any abnormal situation should be promptly removed.